ELECTROMAGNETIC AIR PUMP Brand: Kessel | Category: Water Pump | Size: 1.13 MB Table of Contents Deutsch 2 Table of Contents 2 1 Aufbau der Pumpe 3 Vor Inbetriebnahme 4 Lagerung und Transport 4 Installation 5 Einbauort 5 Elektrischer Anschluss 6 Befestigung 6 Rohranschluss 7 Betrieb 7 3 Wartung 8 4 Servicearbeiten 11 Diagnose und Fehler The JDK-S-60 Air Pump is a replacement for the Secoh EL-S-60. The JDK-S-60 is used in Klargester, MATRIX and Tricel sewage treatment systems along with aeration in ponds. Install instructions for JDK60 Air Blower JDK-S-60 Specification 2 Year Warranty Secoh Air Blower Service Check List Specification Optimal Operating Pressure: 0.20 Bar
SECOH ELS60N and EL60N Air Pump Service Repair Kit eBay
This is a comprehensive update to our popular EL Maintenance Guide, running you through all the tricks to get your Secoh EL Series air pump working again. Secoh EL-60 Septic Air Pump Your Recently Viewed Items Products Other Customers Were Interested In: EL60 - The Secoh Linear Septic Air Pump EL-60. This unit is brand new. Used for aeration on aerobic septic systems. This model has been. The Secoh EL-60 Septic Air Pump rebuild kit is a cost-effective, efficient way to maximize the life of your Secoh EL-60 Septic Air Pump. Quantity Add to cart Order before 2PM for same-day dispatch! Key Features Specs Warranty Your air pump is a critical part of your aerobic septic system. Air pump EL-60n electric diaphragm industrial Add to favorites Compare this product Go to the secoh website for more information Characteristics Fluid air Operation electric Technology diaphragm Domain industrial Other characteristics linear Flow 60 l/min (15.85032 us gal/min) Power 53 W (0.07 hp) Description
CP60W compresseur Hiblow stations EPUR
Description EL-60——EL-150 Voltage:115/230VAC Frequency:60/50Hz Power:46-150W AirFlow:63-150L/min Go to the secoh website for more information Diaphragm linear pump See all secoh products Page 25 INSTRUCTION MANAUAL INSTRUCTION MANUAL ELECTROMAGNETIC AIR PUMP MODEL-SERIES SLL and EL Stand 02/2010 Sach-Nr. 010-814. Page 26 Contents 1. Name Of Parts page 2. Instructions 2.1. Prior to Operation page 2.2. Storage and Transfer page 2.3. Installation page 2.3.1. Instructions To Location Of The Air Pump page 2.3.2. AIR PUMPS Brand: Secoh | Category: Water Pump | Size: 0.64 MB Table of Contents Table of Contents 2 Prior to Maintenance and Service 3 Maintenance 3 Air Filter Cleaning / Replacement 4 Valve Box and Diaphragm Replacement 5 Resetting Auto Stopper 9 Magnet Replacement 10 Diagnosis of Failures 11 Technical Specification 12 EL-S single system EL-S-60N . Integrated overload protection; Protective switch inclusive; Connecting hose included in delivery; Air flow on 100mbar: EL-S-60 (76 l/min) SLL series -20/-30/-40/-50 .. Secoh EL Air Pump Maintenance Guide . Downloads. 380 KB BIBUS Brosch SECOH-Neuheiten 0518.pdf .
Buy Milestone Camping 83150 Electric Air Pump / Inflate Or Deflate Airbeds, Paddling Pools
Description Additional information The Secoh JDK-S-60 linear diaphragm air pump is the replacement to the previous Secoh EL-S-60 (N) versions. Specification Optimal Operating Pressure: 0.20 Bar Optimal Flow: 60 l/min Voltage: 230 VAC Maximum Power Consumption: 40 W Frequency: 50 Hz Sound Level (at 1.5m): 41 db (A) Dimensions: 214 x 185 x 211 mm If you find the same product cheaper elsewhere, we'll match it. The SE60D Diaphragm Kit is suitable for Secoh EL Blowers: EL-S-60N. 2x EL diaphragms, plus their plastic surrounding frame. 4x spacer strips to help with reassembly. Watch how to change a secoh diaphragm below. Maintenance Guide for SECOH Diaphragm Blowers or Pumps - Series JDK-S.
The EL-60n air pump is available in 1 version only : Version "S" to Fault signal on the device shell (standard version) The EL-60n model is an ultra compact model (221 x 177 x 200mm) It has similar performance to the EL-60 model but is much more compact and lightweight (4.4Kg) Features. Power : 53W. Fréquence:50Hz. Caractéristiques Techniques compresseur secoh el-s-60n:. .. MAINTENANCE TECHNIQUE : Le contrôle et nettoyage du filtre à air doit se faire tous les 3 mois à minima et peut être réalisé par l'utilisateur. (Attention, le filtre a un sens de montage ! ) Le remplacement du filtre est à faire s'il reste sale après nettoyage, sinon tous les.
Buy Milestone Camping 83150 Electric Air Pump / Inflate Or Deflate Airbeds, Paddling Pools
Description Pompes à air Secoh Bibus 60N Caractéristiques Produit : Protection de surcharge Interrupteur de protection Avec témoin d'erreur (Option avec signal déporté) Tube de connexion inclus Caractéristiques Techniques : Applications : Stations d'épuration domestique Piégeage des graisses Aération des eaux usées & bain biologique et chimique La pompe à air EL-60n existe en 1 seule version : Version « S » à Signal de défaut sur la coque de l'appareil (version standard) Le modèle EL-60n est un modèle dit ultra compact (221 x 177 x 200mm) Il a des performances similaires au modèle EL-60 mais en beaucoup plus compact et léger (4,4Kg) Caractéristiques. Puissance : 53W