Air Conditioning R22 Pressure Rature Chart Tutorial Pics

You simply consult the R22 RT chart below and see that at 85°F, the pressure of R22 is 155.7 psig. psig or 'pounds per square inch gauge' is a pressure unit we usually in refrigerant temperature pressure charts. Measuring R22 pressure on a hot day in our air conditioner. R22 Pressure-Temperature Chart-49-45: 1-17.2 51: 10.6 101: 38.3-48-44.4 2-16.7 52; 11.1 102; 38.9-47-43.9 3-16.1 53; 11.7 103;. Saturation Pressure-Temperature Data for R22 (psig)* Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C)

R22 Suction And Discharge Pressure Chart

R22 and other common refrigerants is an odorless, colorless gas that will be liquid at sufficiently low temperature and/or high pressure This chart is using outdoor ambient temperature Typical low pressure or suction side, may vary by equipment and metering controls - these are "gauge pressure readings" or "psig" R22 Refrigerant - Properties Properties of Refrigerant R22 Dichlorodifluoromethane - saturated liquid and saturated vapor - imperial and metric units. Refrigerant Compressors - Evaporation Temperature, Condensating Temperature and Capacity Evaporation temperature, condensing temperature and refrigerant compressor capacity. Size. 30 lb. R-22. Cylinder. 50 lb. 125 lb. 1000 lb. 1750 lb. 7th Edition 2020 Refrigerant Reference Guide 17. National Refrigerants, Inc. Product Data Summary and Thermodynamic Tables. Temperature - Pressure Chart for R-22, R-410A, R-407C, R-134A and R-404A Refrigerants SUBJECT: TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009 updated 10/10/2012 Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors.

R22 Pressure Enthalpy Chart

Common refrigerants: temperature - pressure chart (kPa gauge) All data is provided using NIST „REFPROP" Version 9.0 and 9.1. The data is provided without any warranty of any kind. All pressures shown in kPa (gauge 1013mb - sea level). R22 & R22 retrofit replacements Gas R22 R417A (ISCEON® MO59) R422D (ISCEON® MO29) R424A (RS-44) R427A Freon™ Refrigerant For more information on Freon™ refrigerants, visit freon.com The information set forth herein is furnished free of charge and based on technical data that Chemours believes to be reliable. It can replace R22, R417A and R407C with existing oil in system High Ambient and Centrifugal Chillers R-124 100 A1 0 MINERAL OIL or ALKYLBENZENE Similar to R-114 - high ambient air conditioning. R-123 100 B1 0 MINERAL OIL or ALKYLBENZENE Similar to R-11 - low pressure centrifugal chillers 0538-0539_Refrigerants_URI18.qxp 1/26/2018 8:46 AM Page 538 Forane 22 Pressure Temperature Chart Author: Arkema Inc. Subject: Forane 22 Pressure Temperature Chart Keywords: Forane 22, R-22, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas Created Date: 10/4/2012 11:22:02 AM

R22 Pressure Enthalpy Chart The Engineering Mindset

R22 is a single HydroChloroFluoroCarbon (HCFC) compound. It has low chlorine content and ozone depletion potential and a modest global warming potential. ODP1) = 0.05 and GWP2) = 1700 R22 can be used in small heat pump systems, but new systems can not be manufactured for use in the EU after 2003. R-22 and R-410A Operating Pressures, Charging, and Recovery Setup! Updated: Nov 20, 2023 In this article, we will discuss an HVAC unit's refrigerant pressure on both the high side and the low-pressure side while the system runs. Absolute pressure KG/CM2 KPA-G Gauge pressure T T T PSIG KG/CM2 Mbar Pascals PSIA Dew Bbl Farenheit Celsius Kelvin Dew Bbl Dew Bbl Refrigerant R-22 Pressure / Temperature chart Absolute pressure KPA Gauge pressure KG/CM2 KPA-G T T T HVACSuite.com Refrigerant Pressure - Temperature Chart Home > FYI #289 Refrigerant Pressure - Temperature Chart Pressure values are displayed for R-22, R-410a, R-407c, R-134a and R-404a refrigerants. Fahrenheit Celsius R-22 R-410a R-407c R-134a R-404a 155 68.3 405.4 645.2 456.6 281.0 484.8 150 65.6 381.7 607.6 430.3 262.8 456.8 145 62.8 359.1 571.7 405.1 245.6

R22 Gauge Readings Chart

R-22 was invented by a partnership with General Motors and DuPont back in the 1930's. In the 1950's the use of R-22 exploded and for nearly sixty years it was THE refrigerant to be used in home, office, and commercial air conditioning. Along with air conditioning it was also used in chillers, ice rinks, and many other applications. The term gauge signifies that the pressure has been read from a gauge that actually measures the difference between the pressure of the fluid or gas and the pressure of the atmosphere. Psig is equal to psis at sea level (14.7 psi). Psig is equal to psia - 14.7 at sea level. Psia is absolute pressure, which means it is gauge pressure + 14.7 psi.