LONGSIN 4wire Network Photoelectric Smoke Detector Alarm with Relay Output LS82816L

TSS8030R is a smoke detector, designed for early warning of a fire condition. It responds to fixed threshold smoke concentration detected in the protected rooms. The principle of functioning of the detector is based on infrared rays distraction caused by smoke particles entering the optic chamber. The smoke sensitivity is factory preset. Description. CLIPSAL 755RB | Relay Base for 240v Smoke Alarm. The 755RB is an optional accessory for the 755PSMA4 or 755RLPSMA4 Clipsal smoke alarms to offer integration with 3rd party devices such as lights, sirens and home automation systems. The relay base offers this functionality through a changeover, voltage free contact as well as remote.

Conventional Smoke Detector with Relay Output (SNC300SP)

Features Specifications The Brooks EIB128RBU base has the following features: For use with 3000, 140RC and 160e Series alarms Facilitates bulky wiring and conduits Built-in 5A Relay with Pulse or Continuous modes of operation Rechargeable lithium battery back-up Related Information: Data Sheet Related Products Optional Mains Powered Base with Relay Output for 140 Series Detectors.. People Also Bought. Photoelectric 240-volt Smoke Alarm with. Fire Blanket Location - Small Sign - 150. FlameStop 2.5kg ABE Powder Type Portable. ABE Dry Chem Identification - Plastic Sign. Log book cabinet with 003 lock . LED Emergency Surface Mount Light . Smoke Detector 4-wire with relay output DC powered Security system wired Smoke detector with relay output [FT-142] - $10.50 : China top brand burglar and fire alarm systems, New technology burglar and fire alarm security systems Free technical support for shopping and installing security systems. Burglar Alarm Controller Fire Alarm Systems The smoke detector of Series ES Detect used in the detector base can be reset manually or automatically by a short interruption (4 seconds) of the detector voltage. A typical use for this detector is to monitor mobile communication stations, e.g. BTS base transceiver stations.

ARITECH 700 Series Conventional Optical Smoke Detector w/ Relay Output

Smoke Detectors with Sounder and Relay Option System Sensor i3TM sounder and relay smoke detectors apply the guiding principles of installation ease, intelligence, and instant inspection in a series of specialty conventional devices. Features 85 dB sounder Form C relay Isolated thermal sensor Plug-in design (base included) In-line terminals Learn all about the System Sensor i³™ Series 4-Wire Smoke Detector with Fixed Thermal Sensor, Relay. Click to find product details, documentation, ordering info and more. TSS8030R is a smoke detector with dry contact relay output and IP30 protection. Buy from a distributor. Description. TSS8030R is a smoke detector, designed for early warning of a fire condition.. The smoke sensor has a relay output and can be used with controllers which have digital inputs in "dry contact" mode. Features. Conventional Optical + Thermal Detector with relay - DP721R Aritech™. 0. 72,02 € *VAT included*. Conventional optical smoke detector with relay output, Dirt compensation with removable and replaceable optical chamber without the need for calibration, SKU: DP721R. Add to cart. Add to wish list. Description.

4Wire Smoke & Heat Detector with Relay Output FT143Professional Conventional and Intelligent

246 Product Results 2012JA Photoelectric Smoke Detector 20μAOptical Smoke Detector 22051E/EI Photoelectric Smoke Detector 25142-SMOKE 251581 Optical Smoke Alarm 300 Series Conventional Thermal Detector 300 Series Photoelectric Smoke Detector 50μA Optical Smoke Detector 5193 Series V-Plex® Addressable Smoke Detector Detail Documents The Kidde SM120X can be used to activate auxiliary warning devices such as external bells and sirens, hallway or stairway lighting. This relay will only activate when it receives a smoke signal from an interconnect Smoke Alarm. FIRE SAFETY MADE SIMPLE. Learn the Basics IF YOU HAVE QUESTIONS, FIRE AWAY. Visit the Kidde Help Center TSS8030R smoke detector is designed for early warning of a fire condition responding to fixed threshold smoke concentration detected in the protected premises. The smoke sensitivity is factory preset. The principle of functioning of the detector is based on infrared rays distraction caused by smoke particles entering the optic chamber. 12/24Vdc operation, 4-wire. 85dB electronic horn with a temporal 3 pattern. Form C relay contact for security panel monitoring. Interconnectable up to 12 units. Visual alarm and power indicator. ULC listed to CAN/ULC-S531. Built-in 8 second delay on relay activation. This smoke detector is designed to respond to a broad range of fires while.

Optical Smoke Detector ES Detect with relay contact, 48 V DC operation

Smoke Detector Specifications Electrical Specifications Operating Voltage Maximum Ripple Voltage Standby Current Peak Standby Current Maximum Alarm Current The fire detector is controlled by a microprocessor, operating on the basis of an algorithm for self-compensation of the chamber contamination. The smoke sensor has a relay output and can be used with controllers having digital inputs in "dry contact" mode. Features * Smoke sensitivity complies with EN 54-7:2000+ A1:2002;